Triplett 3281 Datový list

Procházejte online nebo si stáhněte Datový list pro Testery kabelové sítě Triplett 3281. Triplett WireMaster Mapper Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 24
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
WireMaster
Mapper
8-Way Wire &
Cable Mapping Kit
Instruction Manual
TRIPLETT
84-876
3/09
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - TRIPLETT

WireMasterMapper8-Way Wire &Cable Mapping KitInstruction ManualTRIPLETT84-8763/09PDF compression, OCR, web optimization using a watermarked evalua

Strany 2 - 1. FEATURES

10flash. If the BATTERY TEST LED does not flash, the battery shouldbe replaced. If it is weak, it may produce erroneous results in theCABLE MAP mode.V

Strany 3 - (w/ optional Hound Tracer)

11Note: The WireMaster Mapper does not test for reversed polarityDC voltages. If reversed polarity DC is present, the WireMasterMapper will not proper

Strany 4 - 3. WARNINGS AND CAUTIONS

12At the ends of the target cables opposite the Remotes, connectthe WireMaster Mapper, in succession, to each cable, noting theID number of the LED th

Strany 5 - 4. SPECIFICATIONS

13The WireMaster Mapper is equipped with the necessary adaptorsand Remotes to test cables with BNC, F, and RJ11/RJ45 connec-tors. It also includes Cli

Strany 6

14not necessarily through all of the ports.For distribution systems using fully power passive splitters, theWireMaster Mapper will map individual R

Strany 7

15test signal or alters the characteristics of the signal.Continuity TestingThe WireMaster Mapper can be used as an audible and visualContinuity test

Strany 8 - 5. CONTROL LOCATIONS

16The WireMaster Mapper performs its ID test using only the cen-ter two conductors of the RJ connector. The OPEN and SHORT /CONTINUITY tests are only

Strany 9 - 6. GETTING STARTED

17Generating a Wire Tracing SignalThe WireMaster Mapper can be used to generate a Wire Tracingsignal. This signal is compatible with the Triplett Houn

Strany 10 - 7. DETAILED OPERATION

188. Included ItemsThe following items are included with the WireMaster MapperDescription Part NumberBNC Remote 1 …………………………… 3274-1BNC

Strany 11

19Description Part NumberRJ11 / RJ45 Remote 1 …………………… RMT-RJ/M-1RJ11 / RJ45 Remote 2 …………………… RMT-RJ/M-2RJ11 / RJ45 Remote 3 ……………………

Strany 12

2TABLE OF CONTENTS1. Features ...…………………... 22. Introduction …………………... 43. Warnings and Cautions ...

Strany 13

20Also AvailableBNC Remotes 1-8 ………………………... 3274-9F Remotes 1-8 ……………………...…… RMT-F/F-9RJ11 / RJ45 Remotes 1-8 ……...……….. RMT-RJ/M-9Clip Lead

Strany 14

21MaintenanceNo regular maintenance of the WireMaster Mapper is required.In the event the product is defective or is damaged, please con-tact Triplett

Strany 15

22Triplett One Year Limited WarrantyTriplett / Jewell Instruments warrants instruments and test equipmentmanufactured by it to be free from de

Strany 16

23The purchaser agrees to assume all liability for any damages and bodilyinjury which may result from the use or misuse of the

Strany 17

24PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Strany 18 - 8. Included Items

3• Tests for Opens and Shorts• Audible and Visual Continuity Test• Generates Warble signal for Wire Tracing (w/ optional Hound Tracer)• AC/DC Over

Strany 19

42. INTRODUCTIONThe Triplett WireMaster Mapper is an 8-Way Cable Mapping Kit,with built-in Continuity beeper, and 120VAC line cross protection.The Ma

Strany 20 - Also Available

54. SPECIFICATIONS• Identifies 8 individual Remotes (BNC, F, RJ, and Cliplead Types, total 32 Remotes) by measuring their precision resistance• A

Strany 21 - Maintenance

6Note: The WireMaster Mapper will not map coaxial cables if anyof the following devices are in use:• Amplifiers • Electronic Switches• Attenuators • M

Strany 22

7Some Typical Cable/Wire ResistanceselbaCepyTrepsmhO.tF0001tseTxaMhtgneLU/6-GRA4961nedleBsmhO4.7 tf000,72U/6-GRA2511nedleBsmhO03 tf006,6U/85-GRA6087ne

Strany 23

85. CONTROL LOCATIONSCABFEDGA: Open LED E: 1 thru 8 ID LED’sB: Unlock Button F: Short/Continuity LEDC: Function Switch G: BNC ConnectorD: Overload

Strany 24

96. GETTING STARTEDInstalling / Replacing BatteryTo install or replace the 9 volt battery, remove the single screwfrom the back of the case. Gently r